Anti-Magnetic Small Current Transformer

As the winding coil is protected by metal shielding inside the plastic case, the measurement accuracy will not be affected in magnetic field as strong as 300mT. Therefore, this kind of small current transformer is very suitable for anti-tamper energy meters. The busbar, with Φ6.2mm two holes and 21mm hole distance, is removable, which is very convenient in assembly.

Anti-Magnetic Small Current Transformer
Anti-Magnetic Small Current Transformer

Anti-Magnetic Small Current Transformer

Features

  • Work properly under 300mT magnetic field
  • Phase shift error < 5′, DC tolerance < 3%
  • High accuracy with turns ratio 1:2500
  • Maximum primary current as high as 80A
  • Plastic case with removable busbar, easy to install

Applications

  • Anti-tamper energy meters
  • Single/three phase electricity meters
  • Electrical measuring instruments

Specifications

Part NumberDI80-25A
Description Anti-Magnetic Small Current Transformer
Structure Of Winding Toroidal
Phase Single
Input / Output 10(80)A/4mA
Max. Current 80 A
Turns Ratio 1:2500
Phase Shift Error5′ (20% Rated Current)
Burden (Rb) 20 Ω
Accuracy Class 0.1 Class
DC Resistance (25°C)125 Ω ± 10%
DC Immunity Test<3%
Anti-magnetic Performanceupto 300mT
Core Inside Nanocrystalline & Fe-based Amorphous
Encapsulation Plastic Case & Epoxy Resin Filled
Busbar Type Removable
Mounting Method Through-holes For Mounting
Application Meters, Instruments
Accept Customized Yes

Dimensions

Dimensions of Anti-Magnetic Small Current Transformer
Dimensions of Anti-Magnetic Small Current Transformer